해외 우수한 분석, 측정, 계측기기 제조회사의 독점 대리점 !

| Model | H311 | 
|---|---|
| Spectral range | Channel 1: 0.93 - 1.1 μm / channel 2: 0.75 - 0.93 μm *) Channel 1: 0.99 μm/ channel 2: 0.78 μm | 
| Temperature ranges | 600 - 1100 °C | 
| 650 - 1300 °C | |
| 750 - 1400 °C | |
| 900 - 1800 °C | |
| 1000 - 2000 °C | |
| 1100 - 2200 °C | |
| 1300 - 2500 °C | |
| 1600 - 3300 °C *) | 
| Pyrometer | Specification | 
|---|---|
| Uncertainty (ε = 1, t90 = 1s, TA = 23°C) | 0.5% of measured value in °C + 1K | 
| Repeatability (ε = 1, t90 = 1s, TA = 23°C) | 0.2% of measured value in °C + 1K | 
| Detector | 2 x Sillicon | 
| Response time t90 | < 80 μs, adjustable up to 10 s | 
| Emissivity ε | 0.050 - 1.200 (per channel, corresponds 5-120% in 0.1% steps) | 
| Analog output | 2 configurable analog outputs 0 or 4?20 mA, max. load: 500 Ω Resolution 0.0015% of the adjusted temperature (16 Bit) | 
| Serial Interface | RS485 (max. 921 kBd), resolution 0.1°C or 0.1°F | 
| Ambient temperature | Operation: 0 to 60°C (32 to 140°F), Fiber optic and optics on optics side: -20 to 250°C (-4 to 482°F) | 
| Relative humidity | No condensing conditions | 
| Power requirement | 24 V DC (18 - 30 V DC), max. 6 VA; protected against reverse polarity | 
| Isolation | Voltage supply, analog and digital outputs are galvanically isolated from each other | 
| Housing / protection class | Aluminum, IP65 to DIN 40 050 with connector | 
| Weight | 650 g | 
| CE label | According to EU directives for electromagnetic immunity | 
| Laser targeting light | (optional) red, 650 nm, P< 1 mW, class II to IEC 60825-1 | 
| Focusable Optics | |||
|---|---|---|---|
| Optics | Measuring distance a [mm] | Spot size M [mm] | |
| < 1200°C | ≥ 1200°C | ||
| OQ11-A1 | 340 mm | 1.5 mm | 0.9 mm | 
| 500 mm | 3 mm | 1.7 mm | |
| 750 mm | 4 mm | 2 mm | |
| 1000 mm | 5.6 mm | 2.8 mm | |
| 2000 mm | 10 mm | 4.6 mm | |
| 3000 mm | 17 mm | 8.8 mm | |
| OQ11-F1 | 1000 mm | 4.8 mm | 2.7 mm | 
| 5000 mm | 26 mm | 14.5 mm | |
| 10000 mm | 51 mm | 29 mm | |
| Focusable Fiber Optics (25 mm outside diameter) | |||
|---|---|---|---|
| Optics | Measuring distance a [mm] | Spot size M [mm] | |
| < 1200°C | ≥ 1200°C | ||
| OQ25-B1 | 240 mm | 2 mm | 1 mm | 
| 500 mm | 3.7 mm | 2.5 mm | |
| 750 mm | 5.6 mm | 3.8 mm | |
| 1000 mm | 7.7 mm | 5 mm | |
| 2000 mm | 15.4 mm | 10 mm | |
| 3000 mm | 23 mm | 15 mm | |
| Focusable Fiber Optics (Miniature 12 mm) | |||
|---|---|---|---|
| Optics | Measuring distance a [mm] | Spot size M [mm] | |
| < 1200°C | ≥ 1200°C | ||
| OQ12-C0 | 120 mm | 2.2 mm | 1.2 mm | 
| 250 mm | 5 mm | 2.5 mm | |
| 500 mm | 12 mm | 6 mm | |